0.75 kW Single Phase Frequency Inverter VFD
- Phase:
- Single/Three phase
- Input voltage:
- 220/380V, 230/400V ±20% or customized
- Output voltage:
- 220/380V, 230/400V ±1-5%
- Frequency:
- 50/60Hz
- Power factor:
- 0.8-1
- Type of technology:
- Servo type with roller carbon brush
- Type of regulation:
- Independent voltage control
- Display:
- LED/Touch Screen HMI
- Installation:
- Indoor/Outdoor
Model NO. | 0.75 kW Single Phase Frequency Inverter VFD | Nature of DC Power | Voltage Variable-Frequency Drive |
Function | Simple Type | Brand | Modern |
Trademark | Modern | Specification | CE,ISO 9001-2008,RoHs,sGs etc |
Origin | china |
MODERN Frequency Converters are available in several different configurations to suit any frequency conversion need. Inputs and outputs are available in any combination of 50, 60, and 400 Hz. Frequency converters are very commonly used to test products designed for use in a different country before it is shipped. Using a frequency converter allows you to precisely emulate the grid power of your target environment in a controlled laboratory setting. They may also be employed when powering machinery from overseas.
Features:
· Frequency Conversion
· Voltage Conversion
· Special Phase Conversion; 1 Phase To 3 Phase, and 3 Phase To 1 Phase
· Well protection and fault alarm function
· Complete Electrical Line Isolation
· True Sine Wave Output
· Quick response time <20ms
· High accurate output voltage and frequency
Circuit mode | IGBT/PWM pulse width adjustment mode |
Wire system | 3-phase-5-wire-system |
Input voltage | Phase to phase: 265-495V |
Input frequency | 30-70Hz |
Output voltage | Phase to phase: 380V |
Output frequency | 50/60Hz, 400Hz optional |
Frequency stability | ≤±0.01% |
Insulation resistance | Above 500Vdc 20MΩ |
Pressure endurance insulation | 1800Vac/5Ma/1minute |
Cooling device | Compulsive fan cooling |
Noise | <55dB |
Wave deformation | ≤2% |
Reaction time | Dynamic response quick, when load 0-100% change, the steady-state response time <20ms |
Efficiency | Efficiency more than 90%, be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads |
Protective device | The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm |
Display | Digital frequency meter, Digital voltage meter, Digital current meter, Digital power/PF meter |
Ambient temperature operating | -10 °C to +50 °C |
Altitude | <1500m |
Relative humidity | <90% |