3.7 kW Single Phase Frequency Inverter VFD

Phase:
Single/Three phase
Input voltage:
220/380V, 230/400V ±20% or customized
Output voltage:
220/380V, 230/400V ±1-5%
Frequency:
50/60Hz
Power factor:
0.8-1
Type of technology:
Servo type with roller carbon brush
Type of regulation:
Independent voltage control
Display:
LED/Touch Screen HMI
Installation:
Indoor/Outdoor
Model NO. 3.7 kW Single Phase Frequency Inverter VFD Nature of DC Power Voltage Variable-Frequency Drive
Function Simple Type Trademark Modern
Specification CE, ISO 9001-2008, RoHS, SGS etc Origin China

3.7 kW Single Phase Frequency Inverter VFD

3.7 kW Single Phase Frequency Inverter VFD

3.7 kW Single Phase Frequency Inverter VFD

MODERN Frequency Converters are available in several different configurations to suit any frequency conversion need. Inputs and outputs are available in any combination of 50, 60, and 400 Hz. Frequency converters are very commonly used to test products designed for use in a different country before it is shipped. Using a frequency converter allows you to precisely emulate the grid power of your target environment in a controlled laboratory setting. They may also be employed when powering machinery from overseas.

Features:

·  Frequency Conversion

·  Voltage Conversion

·   Special Phase Conversion; 1 Phase To 3 Phase, and 3 Phase To 1 Phase

·   Well protection and fault alarm function

·   Complete Electrical Line Isolation

·   True Sine Wave Output

·   Quick response time <20ms

·   High accurate output voltage and frequency

Circuit mode IGBT/PWM pulse width adjustment mode
Wire system 3-phase-5-wire-system
Input voltage Phase to phase: 265-495V
Input frequency 30-70Hz
Output voltage Phase to phase: 380V
Output frequency 50/60Hz, 400Hz optional
Frequency stability ≤±0.01%
Insulation resistance Above 500Vdc 20MΩ
Pressure endurance insulation 1800Vac/5Ma/1minute
Cooling device Compulsive fan cooling
Noise <55dB
Wave deformation ≤2%
Reaction time Dynamic response quick, when load 0-100% change, the steady-state response time <20ms
Efficiency Efficiency more than 90%, be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads
Protective device The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm
Display Digital frequency meter, Digital voltage meter, Digital current meter, Digital power/PF meter
Ambient temperature operating -10 °C to +50 °C 
Altitude <1500m
Relative humidity <90%

3.7 kW Single Phase Frequency Inverter VFD

3.7 kW Single Phase Frequency Inverter VFD

3.7 kW Single Phase Frequency Inverter VFD

3.7 kW Single Phase Frequency Inverter VFD