More Power by Saving Energy

Lower your utility bills starting on the day the equipment is installed, fast and easily, minimizing downtime

400kVAR Power Factor Correction Device PFC

Phase:
Single/Three phase
Input voltage:
220/380V, 230/400V ±20% or customized
Output voltage:
220/380V, 230/400V ±1-5%
Frequency:
50/60Hz
Power factor:
0.8-1
Type of technology:
Servo type with roller carbon brush
Type of regulation:
Independent voltage control
Display:
LED/Touch Screen HMI
Installation:
Indoor/Outdoor

400kVAR Power Factor Correction Device PFC 400V 50Hz with OEM

Description:

With other harmonic filtering solutions, expensive and time consuming site data collection, power quality surveys and computer generated studies are usually needed. Most harmonic filters are designed to accommodate just one or a few harmonic orders. The MODERN Active Power Filter(APF) corrects a full range of harmonic orders, and will not create a resonance condition with existing equipment.

The APF injects compensating current into the load to restore the sine wave and dramatically reduce distortion to less than 5% THD. Its high speed process cancels high frequency output current, while it determines the precise value of injected load current.

The MODERN APF provides the simplest and most effective means to mitigate harmonics, reduce process-related voltage fluctuations, and improve equipment operating life and system capacity.


We are Manufacturer which specialized in Servo Voltage Stabilizer, ninterruptible Power Supply (UPS), Active Power Filter, etc for nearly 40 years. And be vendor of Mitsubishi Elevator in East Africa, GE, Emerson.

Applications:

  • Computers and Peripherals
  • Variable Frequency Drives (VFDs)
  • Welding Machines
  • Uninterruptible Power Supplies
  • Frequency Converters
  • DC Power Systems/Chargers

Specifications:

  • Voltage ratings from 208 to 480vac
  • 25 to 300 amp ratings
  • Cancels 3rd to 51st orders
  • Graphics display and analyzer
  • Individual or parallel systems for added capacity
  • NEMA 1, 12, 3R enclosure ratings

Competitive Advantage:

  • Immediately improves electrical system efficiency
  • Reduces operations and maintenance costs
  • Quick and easy installation, with virtually no downtime
  • No need for complex site analysis
  • Dynamically corrects a wide spectrum of harmonic orders

400kVAR Power Factor Correction Device PFC

FAQ

Feedback

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.