We Manage Voltage, You Save Energy

Optimize energy usage, lowering electricity and maintenance costs, extending eletrical equipment's lifetime

10 kVA Voltage Optimiser

Phase:
Single/Three phase
Input voltage:
220/380V, 230/400V ±20% or customized
Output voltage:
220/380V, 230/400V ±1-5%
Frequency:
50/60Hz
Power factor:
0.8-1
Type of technology:
Servo type with roller carbon brush
Type of regulation:
Independent voltage control
Display:
LED/Touch Screen HMI
Installation:
Indoor/Outdoor

Overview

  Due to extensive use of energy saving lamps and lanterns, computers, convertible frequency air-conditioner, variable-frequency motor, UPS, EPS and loads like these kind in places such as commercial buildings, shopping malls, big stores/supermarkets, office buildings, gymnasiums, securities finance companies, computer rooms and factory production line, massive 3rd harmonics is being produced although we can save energy by these loads for certain percent.

  The harmonics not only pollutes the network, making power quality worse but also affects the normal function of sensitive electronic equipment. Besides, 3rd harmonic is zero sequence harmonic, which would superimpose on the neutral line, and eventually have over current risk, it will pose potential safety hazard to equipment and transmission lines and easily cause fire disaster.

  The Neutral Current Eliminator(NCE) consists of harmonic excluder which have special magnetic circuit structure and its aid-part, it can effectively eliminate 3rd harmonics and reduce input and output neutral current to 0 A.

Features

  • Diverts the flow of harmonic current away from neutral and upstream transformer
  • Reduce high neutral current and neutral-ground voltage
  • Reduce loss and operating temperature
  • Save energy by reducing harmonic losses
  • Prevent voltage flap-tapping caused by non-liner loads
  • Improve power factor

Technical Specifications

1. Input / Output voltage: 380V (400V) / 380V (400V)

2. Neutral current reduction: 100%

3. Third harmonic reduction: ≥ 90%

4. Insulation class: H

5. Rated insulation level: 3KV/min

6. Insulation resistance: ≥ 20MΩ

Application

Shopping centers,

Super markets,

Office building

Big commercial LED monitor, LED lights

Commercial and office buildings

Industrial factories

Any places that have high neutral current issues addressed by harmonics

10 kVA Voltage Optimiser

10 kVA Voltage Optimiser

10 kVA Voltage Optimiser

10 kVA Voltage Optimiser

FAQ

Feedback

This site uses cookies